This is the question we hear most: “Will my switchboard cope?” A large oven does not necessarily mean a large supply. Here is how to reason, with figures.

6 min readUpdated 18 November 2026Alsace Polish Meca
Powder coating oven power and your electricity supply

1. Power and current

On 400 V three-phase, the current per phase is I = P ÷ (1.73 × 400). For heating elements, kW and kVA are practically the same.

Heating powerCurrent per phaseBRELSAS plug
6 kW≈ 8.7 ACEE 16 A
9 kW≈ 13 ACEE 16 A
12 kW≈ 17.3 ACEE 32 A
15 kW≈ 21.7 ACEE 32 A
18 kW≈ 26 ACEE 32 A

Add the fan (less than one kilowatt). The oven always goes on a dedicated circuit with a suitable breaker and a 30 mA RCD; your electrician sizes the cable for the run length.

2. Your supply sets the ceiling

A business on three-phase typically has a contracted power of 12 to 36 kVA (in France, above that a dedicated tariff applies). Everything running at the same time adds up: compressor, booth extraction, lighting, other machines. The oven must fit in what is left, with a margin.

Example: 18 kVA supply, 3 kW compressor and 1.5 kW extraction running. About 13.5 kVA remains, minus a 1.5 kW margin: a 12 kW oven fits, a 15 kW oven does not.

3. If your supply is tight

  • Choose a lower power: at BRELSAS the S comes in 6 to 12 kW, the M and XL in 9 to 18 kW, all at the same price. Same maximum temperature, slower heat-up.
  • Do not run everything at once: start the oven heat-up while the compressor is off, for instance.
  • Increase your contracted power: possible, but it raises the monthly standing charge and sometimes requires work.

4. What does a slower heat-up change?

Heat-up takes longer, especially for the first cycle of the day. Once hot, the oven only uses energy to make up its losses, so the gap narrows on the following cycles. For a workshop running a few cycles a day, it is often a good compromise.

Before ordering: ask your electrician for your contracted power, the space in the switchboard and whether a 16 A or 32 A circuit can be run. Then try our power calculator.

Read next

What does a powder coating curing cycle cost?

What does a powder coating curing cycle cost?

Work out the energy use and cost of a curing cycle: heat-up, curing time, price per kWh. A worked example and tips to cut the bill.

Read the guide
Starting powder coating in your own workshop: steps, equipment, safety

Starting powder coating in your own workshop: steps, equipment, safety

Preparation, electrostatic coating, curing and inspection: the powder coating steps, the minimum equipment, the space needed and the safety rules.

Read the guide
Powder coating cure temperature and time

Powder coating cure temperature and time

What temperature to cure powder coating at, for how long, and why the clock starts when the part is hot, not the air. Undercure, overcure, outgassing.

Read the guide

Come and meet the maker.

By appointment in Staffelfelden, 20 minutes from Mulhouse, Basel and Freiburg. We go through your project together, you see the ovens being built and leave with a clear answer.

CallConfigure